Technical data sheets
Aluminium Alloy | ASTM & FED-QQ
QQ-A-250/4 '0' Sheet
A medium to high strength alloy with, dependent upon temper, minimum Proof Stress up to 57 ksi / 390 Mpa and minimum Tensile Strength up to 66 ksi / 455 MPa
Chemical Composition
SAE AMS QQ-A-250/4 Alloy QQ-A-250/4 |
|
---|---|
Chemical Element | % Present |
Aluminium (Al) | balance |
Other (Each) | 0.05 max |
Chromium (Cr) | 0.1 max |
Titanium (Ti) | 0.15 max |
Others (Total) | 0.15 max |
Titanium + Zirconium (Ti+Zr) | 0.2 max |
Zinc (Zn) | 0.25 max |
Silicon (Si) | 0.5 max |
Iron (Fe) | 0.5 max |
Manganese (Mn) | 0.3 - 0.9 |
Magnesium (Mg) | 1.2 - 1.8 |
Copper (Cu) | 3.8 - 4.9 |
Alloy Designations
Aluminium alloy QQ-A-250/4 has similarities to the following standard designations and specifications:
AMS 4035, Alloy 2024, UNS A92024
Temper Types
Alloy QQ-A-250/4 is supplied in a wide range of tempers:
- O
- T3
- T42
- T81
- T351
- T4
- T62
- T851
- T361
- T72
- T861
Supplied Forms
Alloy QQ-A-250/4 is supplied in plate and sheet
- Plate
- Sheet
Generic Physical Properties
Physical Property | Value |
---|---|
Density | 2.74 g/cm³ |
Melting Point | 640 °C |
Thermal Expansion | 23.1 x10^-6 /K |
Modulus of Elasticity | 73 GPa |
Thermal Conductivity | 193 W/m.K |
Electrical Resistivity | 50.5 % IACS |
Mechanical Properties
SAE AMS QQ-A-250/4 Sheet - |
|
---|---|
Mechanical Property | Value |
Proof Stress | 97 Min MPa |
Tensile Strength | 221 Min MPa |
Elongation A50 mm | 12 Min % |
Mechanical Properties shown are for '0' temper in thicknesses over 0.2mm up to and including 12.6mm
Download PDF
Last updated Thursday, December 5, 2013
Disclaimer
This Data is indicative only and as such is not to be relied upon in place of the full specification. In particular, mechanical property requirements vary widely with temper, product and product dimensions. All information is based on our present knowledge and is given in good faith. No liability will be accepted by the Company in respect of any action taken by any third party in reliance thereon.
Please note that the 'Datasheet Update' date shown above is no guarantee of accuracy or whether the datasheet is up to date.
The information provided in this datasheet has been drawn from various recognised sources, including EN Standards, recognised industry references (printed & online) and manufacturers’ data. No guarantee is given that the information is from the latest issue of those sources or about the accuracy of those sources.
Material supplied by the Company may vary significantly from this data, but will conform to all relevant and applicable standards.
As the products detailed may be used for a wide variety of purposes and as the Company has no control over their use; the Company specifically excludes all conditions or warranties expressed or implied by statute or otherwise as to dimensions, properties and/or fitness for any particular purpose, whether expressed or implied.
Advice given by the Company to any third party is given for that party’s assistance only and without liability on the part of the Company. All transactions are subject to the Company’s current Conditions of Sale. The extent of the Company’s liabilities to any customer is clearly set out in those Conditions; a copy of which is available on request.