Technical data sheets
Aluminium Alloy | BS-L
L93 (AMS 4029) Plate
Applications:
High strength structural components for aircraft , military vehicles and bridges, weapons manufacture, structural applications.
Characteristics:
Heat treatable alloy. High mechanical strength slightly higher than 2011 and 2017A.
Chemical Composition
BS 2L93(1971) Alloy L93 |
|
---|---|
Chemical Element | % Present |
Aluminium (Al) | balance |
Tin (Sn) | 0.05 max |
Lead (Pb) | 0.05 max |
Chromium (Cr) | 0.1 max |
Titanium + Zirconium (Ti+Zr) | 0.2 max |
Zinc (Zn) | 0.2 max |
Nickel (Ni) | 0.2 max |
Iron (Fe) | 0.5 max |
Magnesium (Mg) | 0.2 - 0.8 |
Silicon (Si) | 0.5 - 0.9 |
Manganese (Mn) | 0.4 - 1.2 |
Copper (Cu) | 3.9 - 5 |
Alloy Designations
Aluminium alloy L93 - 2014A is covered by Standard BS EN 2100 and has similarities to the following standard designations and specifications but may not be a direct equivalent:
2014 / 2014A AMS 4029
Temper Types
The most common tempers for L93 - 2014A aluminium are:
- T4
- T6
- T651
Supplied Forms
L93-2014A aluminium is supplied in Plate
- Plate
Generic Physical Properties
Physical Property | Value |
---|---|
Density | 2800 g/cm³ |
Melting Point | 640 °C |
Thermal Expansion | 22.8 x10^-6 /K |
Modulus of Elasticity | 73000 GPa |
Thermal Conductivity | 134 - 135 W/m.K |
Mechanical Properties
These Mechanical Properties apply to plate in the T651 temper
Thickness (mm) | Proof strength (Min) | Tensile Strength (Min) | Elongation % (Min) |
Over 6 up to & incl. 12.5 | 410 | 460 | 7 |
Over 12.5 up to & incl. 25 | 410 | 460 | 6 |
Over 25 up to & incl. 40 | 400 | 450 | 5 |
Over 40up to & incl. 63 | 390 | 430 | 5 |
Over 63 up to & incl. 90 | 390 | 430 | 4 |
Over 90 up to & incl. 115 | 370 | 420 | 4 |
Over 115 up to & incl.140 | 350 | 410 | 4 |
Download PDF
Last updated Thursday, January 9, 2014
Disclaimer
This Data is indicative only and as such is not to be relied upon in place of the full specification. In particular, mechanical property requirements vary widely with temper, product and product dimensions. All information is based on our present knowledge and is given in good faith. No liability will be accepted by the Company in respect of any action taken by any third party in reliance thereon.
Please note that the 'Datasheet Update' date shown above is no guarantee of accuracy or whether the datasheet is up to date.
The information provided in this datasheet has been drawn from various recognised sources, including EN Standards, recognised industry references (printed & online) and manufacturers’ data. No guarantee is given that the information is from the latest issue of those sources or about the accuracy of those sources.
Material supplied by the Company may vary significantly from this data, but will conform to all relevant and applicable standards.
As the products detailed may be used for a wide variety of purposes and as the Company has no control over their use; the Company specifically excludes all conditions or warranties expressed or implied by statute or otherwise as to dimensions, properties and/or fitness for any particular purpose, whether expressed or implied.
Advice given by the Company to any third party is given for that party’s assistance only and without liability on the part of the Company. All transactions are subject to the Company’s current Conditions of Sale. The extent of the Company’s liabilities to any customer is clearly set out in those Conditions; a copy of which is available on request.