Aluminium Alloy   |   BS-L

6L16 H14/H24 Sheet

Commercial1200

6L16 - 1200 is a commercially pure aluminium sheet that may be clad with alloy 7072 for better protection against stress corrosion cracking.


Chemical Composition

BS 6L16(1985)
Alloy 6L16
Chemical Element % Present
Copper (Cu) 0.05 max
Titanium (Ti) 0.05 max
Manganese (Mn) 0.05 max
Other (Each) 0.05 max
Zinc (Zn) 0.1 max
Others (Total) 0.15 max
Silicon + Iron (Si+Fe) 1 max
Aluminium (Al) 99 min

The material shall be supplied cold rolled (temper designation H14), or cold rolled and partially annealed (temper designation H24). No heat treatment is required.


Alloy Designations

Aluminium alloy 6L16 - 1200 is covered by Standard BS EN 6L16 (1985) 


Temper Types

The most common tempers for 6L16 - 1200 aluminium are:

  • H14
  • H24

Supplied Forms

6L16 - 1200 aluminium is supplied in Sheet and Strip.

  • Sheet
  • Strip

Generic Physical Properties

Physical Property Value
Density 2.59 g/cm³
Melting Point 657 °C
Thermal Expansion 23.4 x10^-6 /K
Modulus of Elasticity 69 GPa
Thermal Conductivity 225 W/m.K
Electrical Resistivity 58.5 % IACS
The specification covers sheet and strip of 99% aluminium. The elongation value shown in the mechanical properties table apply to material with nominal thickness 0.4mm up to and including 0.8mm. Different values for additional nominal thicknesses are shown in the specification.

Mechanical Properties

BS 6L16(1985)
Sheet -
Mechanical Property Value
Tensile Strength 110 Min - 140 Max MPa
Elongation A50 mm 3 Min %
Proof Stress 100 Min MPa

The values listed above are for L16 sheet in H14 or H24 condition


Download PDF
Last updated Tuesday, January 7, 2014


Disclaimer

This Data is indicative only and as such is not to be relied upon in place of the full specification. In particular, mechanical property requirements vary widely with temper, product and product dimensions. All information is based on our present knowledge and is given in good faith. No liability will be accepted by the Company in respect of any action taken by any third party in reliance thereon.

Please note that the 'Datasheet Update' date shown above is no guarantee of accuracy or whether the datasheet is up to date.

The information provided in this datasheet has been drawn from various recognised sources, including EN Standards, recognised industry references (printed & online) and manufacturers’ data. No guarantee is given that the information is from the latest issue of those sources or about the accuracy of those sources.

Material supplied by the Company may vary significantly from this data, but will conform to all relevant and applicable standards.

As the products detailed may be used for a wide variety of purposes and as the Company has no control over their use; the Company specifically excludes all conditions or warranties expressed or implied by statute or otherwise as to dimensions, properties and/or fitness for any particular purpose, whether expressed or implied.

Advice given by the Company to any third party is given for that party’s assistance only and without liability on the part of the Company. All transactions are subject to the Company’s current Conditions of Sale. The extent of the Company’s liabilities to any customer is clearly set out in those Conditions; a copy of which is available on request.