Technical data sheets
Aluminium Alloy | BS-L
6L16 H14/H24 Sheet
6L16 - 1200 is a commercially pure aluminium sheet that may be clad with alloy 7072 for better protection against stress corrosion cracking.
Chemical Composition
BS 6L16(1985) Alloy 6L16 |
|
---|---|
Chemical Element | % Present |
Copper (Cu) | 0.05 max |
Titanium (Ti) | 0.05 max |
Manganese (Mn) | 0.05 max |
Other (Each) | 0.05 max |
Zinc (Zn) | 0.1 max |
Others (Total) | 0.15 max |
Silicon + Iron (Si+Fe) | 1 max |
Aluminium (Al) | 99 min |
The material shall be supplied cold rolled (temper designation H14), or cold rolled and partially annealed (temper designation H24). No heat treatment is required.
Alloy Designations
Aluminium alloy 6L16 - 1200 is covered by Standard BS EN 6L16 (1985)
Temper Types
The most common tempers for 6L16 - 1200 aluminium are:
- H14
- H24
Supplied Forms
6L16 - 1200 aluminium is supplied in Sheet and Strip.
- Sheet
- Strip
Generic Physical Properties
Physical Property | Value |
---|---|
Density | 2.59 g/cm³ |
Melting Point | 657 °C |
Thermal Expansion | 23.4 x10^-6 /K |
Modulus of Elasticity | 69 GPa |
Thermal Conductivity | 225 W/m.K |
Electrical Resistivity | 58.5 % IACS |
Mechanical Properties
BS 6L16(1985) Sheet - |
|
---|---|
Mechanical Property | Value |
Tensile Strength | 110 Min - 140 Max MPa |
Elongation A50 mm | 3 Min % |
Proof Stress | 100 Min MPa |
The values listed above are for L16 sheet in H14 or H24 condition
Download PDF
Last updated Tuesday, January 7, 2014
Disclaimer
This Data is indicative only and as such is not to be relied upon in place of the full specification. In particular, mechanical property requirements vary widely with temper, product and product dimensions. All information is based on our present knowledge and is given in good faith. No liability will be accepted by the Company in respect of any action taken by any third party in reliance thereon.
Please note that the 'Datasheet Update' date shown above is no guarantee of accuracy or whether the datasheet is up to date.
The information provided in this datasheet has been drawn from various recognised sources, including EN Standards, recognised industry references (printed & online) and manufacturers’ data. No guarantee is given that the information is from the latest issue of those sources or about the accuracy of those sources.
Material supplied by the Company may vary significantly from this data, but will conform to all relevant and applicable standards.
As the products detailed may be used for a wide variety of purposes and as the Company has no control over their use; the Company specifically excludes all conditions or warranties expressed or implied by statute or otherwise as to dimensions, properties and/or fitness for any particular purpose, whether expressed or implied.
Advice given by the Company to any third party is given for that party’s assistance only and without liability on the part of the Company. All transactions are subject to the Company’s current Conditions of Sale. The extent of the Company’s liabilities to any customer is clearly set out in those Conditions; a copy of which is available on request.